Page 1
CITY OF OSHKOSH No 114218 OSHKOSH ON THE WATER BUILDING PERMIT - APPLICATION AND RECORD Job Address 3555 MOSER ST Owner RHJ JKJ LLC Create Date 05/18/2005 Designer Contractor GANTHER CONSTRUCTION Category 210 - Addition Industrial Plan O8-31-0505 Type Building Sign Canopy Fence Raze Zoning Class of Const: 2Bibc Size 78x68 Unfinished/Basement 0 Sq. Ft. Rooms 0 Height 0 Ft. Projection Finished/Living 5239 Sq. Ft. Bedrooms 0 Stories 1 Canopies 0 Garage 1168 Sq. Ft. Baths 0 Signs 0 Foundation Poured Concrete Floating Slab Pier Other Concrete Block Post Treated Wood Occupancy Permit Required Flood Plain No Height Permit Not Required Park Dedication Not Required # Dwelling Units 0 # Structures 1 Use/Nature of Work Industrial/ 5239 sf office addition w/ 1168 sf basement. * Note: Compliance with Engineer Division Storm Drainage Review letter conditions of approval must be provided. HVAC Contractor Plumbing Contractor Electric Contractor Fees: Valuation $405,663.00 Plan Approval $0.00 Permit Fee Paid $1,282.00 Park Dedication $0.00 Issued By: Date 05/24/2005 Final/O.P. 00/00/0000 Permit Voided Parcel Id # 1519606400 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Agent/Owner Address 4825 CTY TRK A OSHKOSH WI 54901 - 0000 Telephone Number 426-4774 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready.
Page 2
ZONING/LAND USE COMPLIANCE CHECKLIST JOB LOCATION: 3555 MOSER ST PACUR INC. ZONING: M-3 PROPERTY OWNER/CONTRACTOR: PACUR / MARTIN-GANTHER CONSTRUCTION DATA: [ ] New Construction [X] Addition [ ] Alteration TYPE OF CONSTRUCTION: (i.e. fence, pool, parking lot, sign, etc.) 5239 SF OFFICE ADDITION COMPLIANCE CHECKLIST | DEFICIENT | DEFICIENT | DEFICIENT | | :--- | :--- | :--- | | [ ] Use | [ ] Rear Yard | [ ] Landscape Standards | | [ ] Lot Width | [ ] Side Yards | [ ] Height | | [ ] Lot Area | [ ] Building Area | [ ] Conditions of Approval | | [ ] Lot Area Per Family | [ ] Parking Standards | [ ] Compliance with P.C. or BZA Conditions of Approval | | [ ] Floodplain | [ ] Off-Street Loading Standards | [ ] Signage Standards | | [ ] Front Yard | [ ] Vision Clearance | [ ] Mechanical Equip. Screening | | [ ] Front Yard Side Street | [ ] Transitional Yard Standards | [ ] Other | | | [ ] Parking Lot Lighting | | COMMENTS: • Pending Chamco Approval. - See Attached Approval • Updated landscape plan has been approved. REVIEW AUTHORITY As per Section 30-5 Enforcement of the City Zoning Ordinance, the Director of Community Development, or designee, must approve all plans, except the following: (1) Alterations or interior work when the use is conforming and when no change in use is proposed. (2) Maintenance items, e.g. siding, windows, etc., when the use is conforming and when no change is proposed. [X] APPROVED [ ] DENIED _______ Plan Commission Action Required _______ BOA/Variance(s) Required REVIEWED BY: Matt Tucker DATE: 04/20/2005 4-28-05 2003
Page 3
Page 1 of 1 Tucker, Matt W From: Penny K. Wilz Sent: Thursday, April 28, 2005 9:12 AM To: Tucker, Matt W Cc: 'Dean Glatting' Subject: Pacur All-- The Chairman of the Site Plan Review Committee and Chamco Staff approved the addition plans for Pacur Inc. as presented by Dean Glatting of Martin-Ganther Group. Please let me know if anything further is needed from us or we can help in any way. Thanks-- Penny 4/28/2005
Page 4
8-29-04 MARTIN GANTHER GROUP 7225 Wisconsin Avenue, Suite 700 Bethesda, MD 20814 Tel: 301-656-4700 Fax: 301-656-4708 www.martinganth.com OVERALL NORTH ELEVATION 1/16" = 1'-0" OVERALL SOUTH ELEVATION 1/16" = 1'-0" OVERALL EAST ELEVATION 1/16" = 1'-0" MARTIN|GANTHER GROUP Architecture & Project Development Services ENLARGED PARTIAL SOUTH ELEVATION 1/2" = 1'-0" P A C U R ENLARGED PARTIAL EAST ELEVATION 1/2" = 1'-0" PACUR INC. YVONNE NISSE PROJECT DIRECTOR DATE 8 APR 2005 PROJECT NUMBER 04-1065 SHEET A3