Page 1
27 SERIES 4230 ALUMINUM FIXED WINDOW H HARWICO HERMANZA & FL P.O. Box 1516 116 Industrial Ave San Juan, Puerto Rico 00901 Tel: (809) 722-8811 DWG. NO. SW-420-0 SHEET 3 OCTAGON TYPICAL ELEVATION CORNER DETAIL #1 HEXAGON TYPICAL ELEVATION DESIGN PRESSURE CHART - PSF WINDOW SIZE INCHES W/ 720000 PSI ALUM W/ 42000 PSI ALUM PSF PSF PSF PSF NEG. POS. NEG. POS. 48 100.00 150.00 38.00 39.00 -- -- 42 100.00 150.00 48.40 46.40 -- -- 36 100.00 150.00 63.20 60.20 -- -- 30 100.00 150.00 83.50 79.50 -- -- 24 100.00 150.00 121.00 115.00 72.00 72.00 DESIGN PRESSURE CHART - PSF WINDOW SIZE INCHES W/ 720000 PSI ALUM W/ 42000 PSI ALUM PSF PSF PSF PSF NEG. POS. NEG. POS. 48 100.00 150.00 38.00 39.00 -- -- 42 100.00 150.00 48.40 46.40 -- -- 36 100.00 150.00 63.20 60.20 -- -- 30 100.00 150.00 83.50 79.50 -- -- 24 100.00 150.00 121.00 115.00 72.00 72.00 1/4" ALUM. ANGLE (MIN. 1 1/2" MIN.) 1/4" ALUM. ANGLE (MIN. 1 1/2" MIN.) 2 ANGLES PER SIDE (TYPICAL) 2 ANGLES PER SIDE (TYPICAL) CORNER DETAIL A CORNER DETAIL A 45" MAX. 45" MAX. PRODUCTS ENGINEERED TO PERFORM HARWICO HERMANZA & FL SAN JUAN, PUERTO RICO