Page 1
Table 4: Attachment Resistance Expressed as a Moment - M (ft-lb) for Nail-On Systems Tile Profile Fastener Type Direct Deck (Min. 15/32" Plywood) Direct Deck (Min. 19/32" Plywood) Battens Mastic by Atlas 1-1/2" (6mm) Ring Nail 28.6 41.6 21.5 1-1/2" Screw or Screw with Washer 8.1 16.6 8.4 2-1/2" Screw or Screw with Washer 8.9 16.2 7.5 2-1/2" Self-Drilling Screw 23.7 32.2 10.6 3" Self-Drilling Screw 24.1 32.2 10.6 3" Self-Drilling Screw with Washer 28.5 28.3 23.0 Single Nail (10d) 27.6 27.6 22.0 Single Nail (10d Galv) 18.1 36.1 41.6 Single Nail (10d Galv. w/ Washer) Table 5: Attachment Resistance Expressed as a Moment - M (ft-lb) for Two-Ply Adhesive Bat Systems Tile Profile Tile Application Minimum Attachment Resistance Convex/Flat Adhesive 25.0 Volcan by Atlas 1. Two-Ply Adhesive System with 1/8" x 1/8" x 12" battens. 2. Polyurea Protected, 1/8" x 1/8" x 12" battens. Table 5A: Attachment Resistance Expressed as a Moment - M (ft-lb) for Single Ply Adhesive Bat Systems Tile Profile Tile Application Minimum Attachment Resistance Convex/Flat 1. Two-Ply Adhesive System with 1/8" x 1/8" x 12" battens. 2. Polyurea Protected, 1/8" x 1/8" x 12" battens. 30.0 Volcan by Atlas 30.0 Table 5B: Attachment Resistance Expressed as a Moment - M (ft-lb) for Mortar Bat Systems Tile Profile Tile Application Attachment Resistance Convex/Flat Mortar Bat 27.50 NOA No.: M-062644 Expiration Date: 08/20/08 Application No.: 4446 W00171 NOA 08-20V 1 0 5528 08