← Rubio, Marco

Technical Specification — Altas, 04-0025-61 (2006)

6247 SW 14 Clients Ferro Miami-Dade County Building Department Rubio Lobbyist Documents

Open / download PDF

Document text

Page 1
4. INSTALLATION 4.1. Install New Spanlin 'S' Clay Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 720. 4.2. Data For Abutment Calculation Table 1: Average Weight (W) and Dimensions (L x W) Tile Profile Weight (W) (lbs) Length (L) (ft) Width (W) (ft) V-Form by Altas 7.1 1.650 0.833 Table 2: Aerodynamic Multiplier -> X (ft) Tile Profile Batten Application Direct Deck Application V-Form by Altas 0.350 0.250 Table 3: Resulting Moments due to Gravity, M, (ft-lb) 2'-12" 3'-12" 4'-12" 5'-12" 6'-12" 7'-12' or Batten Direct Deck Batten Direct Deck Batten Direct Deck Batten Direct Deck Batten Direct Deck greater Batten Direct Deck Batten Direct Deck Batten Direct Deck Batten Direct Deck Batten Direct Deck 4.75 4.71 5.00 4.95 4.65 4.56 4.51 4.44 4.38 4.30 4.29 4.22 NO. No.: 04-0025-61 Expiration Date: 08/29/09 Approval Date: 08/29/06 Page 3 of 4 M00121 1907 3K 319 S & 0825-911 2