← Rubio, Marco

Technical Drawing — Sunlite Windows Manufacturing, Inc., Series 4230 Aluminum Fixed Window (2000)

6060 SW 13 Clients Ferro Miami-Dade County Building Department Rubio Lobbyist Documents

Open / download PDF

Document text

Page 1
27 Sunlite Windows Manufacturing, Inc. 10000 SW 136th Street Miami, Florida 33176 305-386-8711 305-386-8712 Fax FRANCO HERNANDEZ P.E. H SERIES 4230 ALUMINUM FIXED WINDOW Project No.: MH1 Date: 6-24-00 Scale: 1/2" = 1'-0" Drawn By: JMS Checked By: FHR Project No.: PM-00-00 SHEET 1 OF 3 COMPARATIVE ANALYSIS TABLES ON SHEETS 2 AND 3 BASED ON THE FOLLOWING TESTS: 1) TEST SIZE - 4'6" X 108" 1/4" TEST LOAD = 128.0 = 128.0 PSF WATER TEST = 15.0 PSF WATER INFILTRATION TESTED TESTED DOOR = 0-92-86 2) TEST SIZE - 27" X 74" TEST LOAD = 64.0 = 64.0 PSF WATER TEST = 15.0 PSF WATER INFILTRATION TESTED TESTED DOOR = 0-92-86 3) TEST SIZE - 26 1/2" X 53 1/4" TEST LOAD = 44.0 = 44.0 PSF WATER TEST = 15.0 PSF WATER INFILTRATION TESTED TESTED DOOR = 0-89-86 PART. No. SW-101 GLAZING BEAD 6055-10 SW-102 #12 X 1" HILTI KWIK-FLEX SELF-DRILLING SCREW FOR ANCHORING TO CONCRETE. FOR SPACER INFORMATION ON SHEETS 2 AND 3 SW-101 MIAMI-DADE COUNTY APPROVED WALLS UNDER 60' AND 3 STEEL WITH 1/2" MINIMUM WALL THICKNESS SECTION A-A WOOD BLOCK AT DRYERS MUST BE PROPERLY ANCHORED TO BE REVIEWED BY BUILDING OFFICIAL #12 X 1" HILTI KWIK-FLEX SELF-DRILLING SCREW WITH 1 1/4" MIN. EMBEDMENT INTO WOOD OR 1 1/4" MIN. EMBEDMENT INTO CONCRETE. FOR SPACER INFORMATION SEE ELEVATIONS ON SHEETS 2 AND 3 SW-102 26 1/2" WIDE GLASS OR TEMPERED GLASS 26 1/2" WIDE ANNEALED GLASS SW-101 SW-102 PART. No. SW-102 GLAZING BEAD 6055-10 APPROVED BY: MIAMI-DADE COUNTY PRODUCT CONTROL DIVISION FRANCO HERNANDEZ P.E. EXPIRES 4-1-2003