4
STANDARD ROOF VALLEY DETAIL
2x4 (top)
See note (a)
4x4
2x4 (top)
3x6 (top)
Supporting beams at 2'-0" o.c. max.
NOTES:
(a) Note: Use continuous bridging on verticals only at 3'-0". Connect bridging to verticals w/2-8d nails at each end.
(b) Note: spacing for verticals should be 16" o.c. maximum. Verticals should be spaced at 6'-0" o.c. maximum.
(c) Note: for end support at 4'-0" intervals, use 2x6 with ends at 4'-0" intervals. Use 2x6 with ends at 4'-0" max wall height.
PARTIAL ROOF LAYOUT
VALLEY TRUSS
Supporting Truss
12 Pitch 6 to 7
Valley trusses at 2'-0" o.c. max.
8" wedge nailed 16 truss w/2-8d for ends or level cut bottom chord of valley truss.
Note: Proposed plumbing tray to be installed under valley truss to prevent water damage to ceiling in common area.
REMBERTO CONTRERAS, P.E.
CERTIFIED PROFESSIONAL ENGINEER
STATE OF TEXAS
License No. 33172
Expires 12-31-20
STRUCTURES USA, INC.
(800) 744-8877
1-800-744-8877
NOV 9 2004
Engineering Drawing — Structures USA, Inc., Standard Roof Valley Detail (2004)